Sailhero XHCO2000B Carbon Monoxide Analyzer operates on the principle of gas filter correlation infrared absorption. It is mainly used in the construction of various ambient air quality automatic monitoring stations at all levels, and can continuously and automatically monitor the concentration of carbon monoxide (CO) in ambient air.
Sailhero XHOZ2000B monitor is based on ultraviolet absorption method, and O3 concentration in the air is monitored through the principle that O3 molecules generate electroresponse of different strengths before and after absorbing 254nm ultraviolet light. A hollow glass tube is irradiated by an ultraviolet lamp with an emission wavelength of 254nm; through solenoid valve switching, the glass tube is alternately filled with sample gas and O3-eliminated reference gas. The ratio of light intensity between O3-eliminated reference gas and sample gas is I0/I, through this value, the concentration of O3 can be calculated by Lambert-Beer formula.
Main Characteristics
● Touch-screen control;
● Automatic start-up;
● Manual or remote automatic zero/span calibration;
● The measuring unit is optional, and the measuring range is automatically changed;
● Radiometric techniques eliminates the effects of aging of the light source and contamination of the optical surface of the absorption cell on the measurement results;
● Constant temperature and closed-loop control of the ultraviolet lamp ensure the stability of the luminous intensity of the ultraviolet lamp;
● Auto-diagnosis and alarm function;
● Built-in dynamic data storage function;
● Communication mode selection: RS232 or RS485 serial port and data acquisition instrument carry out data transmission;
● China Environmental Industry Association certified.
Parameters and Indexes
| Measuring range display |
(0~500) ppb, 0-20 ppm (other optional parameters) |
| Unit of concentration |
mg/m3, μg/m3, nmol/mol, μmol/mol, ppm, ppb |
| Zero point noise |
≤0.25 ppb |
| Limit of detection |
≤0.5 nmol/mol |
| Minimum display unit |
0.1 ppb |
| Indication error |
±1.0% F.S |
| Range drift(24h) |
±5 ppb |
| Response time |
<120s |
| Voltage stability |
±1.0% F.S |
| Rate stability |
±10% |
| Precision |
±1.0% of measurement |
| Sampling flow |
0.8 L/min±10% |
| Influence of environmental temperature change (temperature range from 15℃ to 35℃) |
≤1.0 ppb/℃ |
| Power supply |
220VAC±10%,50HZ |
| Concentration deviation between sampling port and calibration port |
±1% |
| Overall dimension (L x W x H) |
56.5cm×48.2cm×13.4cm (without handle and fixing plate) |
| Weight |
12.8 kg |